Wednesday, 21 February 2018

ORA-08004: sequence FND_CONCURRENT_PROCESSES_S.NEXTVAL exceeds MAXVALUE - Oracle EBS R12

https://systemadministratorsys.blogspot.com/2018/02/ora-08004-sequence-fndconcurrentprocess.html

ORA-08004: sequence FND_CONCURRENT_PROCESSES_S.NEXTVAL exceeds MAXVALUE

ERROR


Routine AFPGCP cannot create a process ID for your concurrent manager process ORACLE error 8004 in FDUUID
Cause: FDUUID failed due to ORA-08004: sequence FND_CONCURRENT_PROCESSES_S.NEXTVAL exceeds MAXVALUE and cannot be instantiated.
TheCall to establish_icm failed
The Internal Concurrent Manager has encountered an error.


SOLUTION


The max value for the sequence FND_CONCURRENT_PROCESSES_S has been reached and we need to increase the max value.

For Checking Run the below query



SQL> select FND_CONCURRENT_PROCESSES_S.nextval from dual;

select FND_CONCURRENT_PROCESSES_S.nextval from dual
*
ERROR at line 1:
ORA-08004: sequence FND_CONCURRENT_PROCESSES_S.NEXTVAL exceeds MAXVALUE and
cannot be instantiated



Increase max value Of APPLSYS.FND_CONCURRENT_PROCESSES_S

SQL> ALTER SEQUENCE APPLSYS.FND_CONCURRENT_PROCESSES_S MAXVALUE 99999999;

Sequence altered.